Facts & Figures

 ClientVika BV Cheese specialty industry
 LocationEde, The Netherlands
 Operacion Start2005
 WastewaterIndustrial
 Project TypeGreenfield
 Nereda Design Capacity:
  • Dry Weather Flow250 MLD
  • Peak Flow10 m3/h
  • PE5,000 PE (PE = 60 gBOD/d)

About the Vika BV Nereda WWTP

Vika wanted to reduce wastewater levies and odor nuisance. Based on results of a municipal wastewater pilot, Royal HaskoningDHV designed this first full-scale Nereda and implemented it by retrofitting a milk storage tank into a 100 m3 Nereda reactor.

Contact Us

René Noppeney

Global Director Water Products & Innovation

Nijmegen, NL

Send message Send message

Nereda® Videos

All videos over Nereda® Technology